DSpace Repository

Fracture resistance of resin endocrowns with and without fiber reinforced composite base material: A preliminary study

Show simple item record

dc.contributor.author Kaya Büyükbayram, Işıl
dc.date.accessioned 2024-03-25T08:09:32Z
dc.date.available 2024-03-25T08:09:32Z
dc.date.issued 2023
dc.identifier.issn 2280-8000
dc.identifier.uri http://hdl.handle.net/11547/11411
dc.description.abstract Objective:The aim of this study was to investigate the effects of fiber-reinforced composite base material on fracture resistance and fracture pattern of endodontically treated maxillary premolars restored with endocrowns using two different resin nanoceramic computer-aided design and computer-aided manufacturing (CAD/CAM) restorative material. Methods:Forty extracted sound maxillary premolars with an occlusal reduction of 2 mm above the cementoenamel junction (CEJ) was performed following root canal treatment. Mesial interproximal box was prepared for each tooth at the margin of the CEJ and randomly distributed into four groups (n = 10) as follows: Group A, no resin build-up in the pulp chamber; Group B, 2 mm of fiber-reinforced composite (FRC) build-up (EverX Posterior, GC).; Group C, no resin build-up in pulp chamber; Group D, 2 mm of FRC build-up. Groups A and B were prepared with resin nanoceramic (RNC) consisting ceramic nanofillers (Lava Ultimate 3 M ESPE), while Group C and D were prepared with RNC consisting ceramic nanohybrid fillers (Cerasmart GC Corp). All samples were subjected to 1,200,000 chewing cycles (1.6 Hz, 50 N) and 5000 thermal cycles (5 & DEG;C-55 & DEG;C) for artificial aging on a chewing simulator with thermal cycles (CSTC). Samples that survived the CSTC test without being damaged were subjected to a load-to-fracture test. Results:The highest mean fracture strength was found in Group D (936.0 & PLUSMN; 354.7) and lowest in Group A (684.2 & PLUSMN; 466.9). Fracture strength was higher in groups where FRC was used as a base material than plain restorations. However, there were no significant differences between the Lava and Cerasmart groups with and without FRC (p > 0.05). Most of the samples were irreparably fractured under CEJ. Conclusion:Using short FRCs as a resin base material did not significantly improve fracture resistance. Cerasmart and Lava blocks had similar fracture resistance and fracture pattern. tr_TR
dc.language.iso en tr_TR
dc.relation.ispartofseries 21;
dc.subject ENDODONTICALLY TREATED TEETH tr_TR
dc.subject BIOMECHANICAL CONSIDERATIONS tr_TR
dc.title Fracture resistance of resin endocrowns with and without fiber reinforced composite base material: A preliminary study tr_TR
dc.type Article tr_TR


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account